Alarm module for locking system BGA

0.00

In stock

The module serves to detect an alarm event when locking the doors with electronic system BulKey BKU and electromagnet EMB300 or electromagnetic bolt BKB100.

SKU: BGA Category:

Alarm Module locking systems BKU417, BKU419

Application
The module is used in security doors general inputs of buildings, cellars or other areas. The module serves to detect an alarm event when locking the doors with electronic system BulKey BKU and electromagnet EMB300 or electromagnetic bolt BKB100. The module will trigger the relay when there is a signal that the door is opened while the lock is locked. For example, if the door is locked, and someone with a lever or otherwise break or opening the door will trigger the relay module. Time that will trigger the relay is 5 seconds. (can be changed upon request of customers). To the relay can connect siren or alarm security system to alert and scare the offender.

INSTALLATIONINSTRUCTIONS

The moduleis powered DC voltage (red +12 V; brown GND). Green cable BGA2 connects to the yellow cable to the system BKU and magnetic sensor for door open​​. The orange cable BGA2 module connects to the gray cable BKU and to lock.

Warning: It is desirable that the unit be installed by a qualified person